Archives

  • 2026-11
  • 2026-10
  • 2026-09
  • 2026-08
  • 2026-07
  • 2026-06
  • 2026-05
  • 2026-04
  • 2026-03
  • 2026-02
  • 2026-01
  • Cisapride: Documented Identity and Mechanism

    2026-10-14

    Cisapride is described by APExBIO as a research-use compound with two pharmacological attributes: nonselective agonism at 5-HT4 receptors and inhibition of the human ether-à-go-go-related gene (hERG) potassium channel. Those attributes make the material conceptually relevant to both the 5-HT4 receptor signaling pathway and cardiac electrophysiology research. The distinction between a documented molecular action and an observed cellular or tissue phenotype is essential, however: the available product information does not provide an identity-matched study, quantitative electrophysiology data, or evidence that a particular assay used this product.

    Documented identity and scientific context

    The APExBIO Cisapride listing identifies catalog B1198 as Cisapride and gives the chemical name 4-amino-5-chloro-N-((3S,4R)-1-(3-(4-fluorophenoxy)propyl)-3-methoxypiperidin-4-yl)-2-methoxybenzamide. The listed molecular formula is C23H29ClFN3O4, with a molecular weight of 465.95. The product is described as a solid and as insoluble in water, with higher listed solubility in DMSO and ethanol.

    The related context uses R 51619 as an associated identifier for Cisapride, while the product page itself identifies the catalog material as Cisapride, B1198. That nomenclature association is reported here as provenance information rather than as an independently verified chemical-identification result. APExBIO also reports quality-control documentation including purity greater than 99.7%, HPLC, NMR, and MSDS materials. These supplier-reported specifications describe the marketed material; they do not by themselves establish receptor potency, channel-blocking potency, assay reproducibility, or biological performance in a particular research model.

    Documented mechanism and measurement meaning

    5-HT4 receptor signaling

    The product description characterizes Cisapride as a nonselective 5-HT4 receptor agonist. In mechanistic terms, that is an upstream receptor-level description: it identifies a pharmacological interaction with the 5-HT4 receptor rather than a measured downstream phenotype. A readout described as altered serotonergic signaling would therefore be an observation downstream of receptor engagement, not a direct measurement of chemical identity or receptor binding unless the relevant assay had been independently documented.

    The word “nonselective” is also important for interpretation. It indicates that the product should not be treated as a narrowly exclusive probe of one biological pathway solely on the basis of the product description. The available source does not quantify selectivity across receptor subtypes, establish concentration-dependent effects, or define which downstream signaling components would dominate in a particular cell system.

    hERG channel inhibition and cardiac readouts

    APExBIO separately describes Cisapride as a potent inhibitor of the hERG potassium channel and links that property to investigations of cardiac electrophysiology and drug-induced arrhythmias. hERG channel inhibition is a molecular or channel-level mechanism. By contrast, a change in an electrophysiological trace, contractile pattern, beat interval, or arrhythmia-like phenotype would be a downstream measurement. The latter can be biologically informative, but it cannot be interpreted as a direct measurement of hERG inhibition unless the study establishes that relationship with appropriate mechanistic evidence.

    This distinction matters in cardiac arrhythmia research because a whole-cell or tissue-level phenotype can reflect more than one process. The product description documents hERG inhibition and a research rationale, but it does not provide a specific assay readout, effect size, comparator, exposure-response relationship, or evidence separating hERG-mediated effects from the consequences of 5-HT4 agonism or other pharmacology. No claim about the magnitude or predictiveness of a cardiac phenotype can therefore be drawn from the product page alone.

    Interpretation of the listed product properties

    Claim in the product information What it supports What it does not establish
    Cisapride identity, catalog B1198, formula, and molecular weight A documented catalog-level chemical identity and provenance for the marketed material Independent lot authentication, biological potency, or equivalence to material used in an external study
    Nonselective 5-HT4 receptor agonism A rationale for studying serotonergic receptor signaling A quantitative receptor profile, subtype selectivity map, or defined downstream response in a named model
    hERG potassium channel inhibition A rationale for examining channel-related cardiac electrophysiology and arrhythmia-relevant phenotypes A measured current, waveform change, arrhythmia rate, or translational risk estimate
    Reported purity and HPLC, NMR, and MSDS documentation Supplier-reported quality-control and safety-documentation claims Proof that a biological result is attributable only to Cisapride or that the material reproduces a published assay outcome
    Solubility and stability information Product-characterization information relevant to how the supplier describes the material A recommendation for experimental formulation, handling, storage, or assay implementation

    The solvent-specific solubility statements should not be mistaken for evidence of biological availability in a cell-based or electrophysiological model. Likewise, a supplier-reported purity value is not equivalent to a pharmacological characterization: it does not state whether the remaining material, assay matrix, model choice, or exposure context could influence a measured phenotype.

    Evidence availability and applicability boundaries

    No identity-matched research paper is available in the provided evidence. Accordingly, there are no supported Cisapride-specific sample sizes, replicate counts, uncertainty estimates, dose-response values, electrophysiological effect sizes, or comparator results to report. The related article summaries concern iPSC-derived cardiomyocyte imaging and broader cardiotoxicity-screening concepts, but the available excerpts do not document a named Cisapride experiment with traceable methods and results. They can at most provide measurement-context language; they do not establish that APExBIO’s B1198 material was used or that its listed properties produced a particular imaging or electrophysiological outcome.

    Several boundaries follow from this provenance:

    • The product page supports a documented identity and supplier-described mechanism, not an independent literature consensus.
    • The term “potent” is reported by the supplier, but no potency metric, assay system, uncertainty, or comparator is provided in the available material.
    • Receptor agonism and hERG inhibition are distinct pharmacological claims. Neither one alone specifies the phenotype that would appear in a particular cell, tissue, or computational measurement.
    • A cardiac electrophysiology result, if reported elsewhere, would need to be evaluated for model, endpoint, comparator, exposure context, and mechanistic attribution before being generalized to Cisapride or to clinical arrhythmia risk.
    • The supplier’s quality-control documents establish provenance claims for the product listing but do not substitute for identity-matched biological validation.

    Factual synthesis

    Cisapride, identified in the related context as R 51619, is listed by APExBIO as a nonselective 5-HT4 receptor agonist and hERG potassium channel inhibitor. These two claims define a plausible conceptual scope spanning the 5-HT4 receptor signaling pathway and cardiac electrophysiology research, with particular relevance to mechanistic studies of drug-induced arrhythmia phenotypes. The available information does not, however, document a Cisapride-specific experiment or establish quantitative performance in any cardiac, serotonergic, imaging, or electrophysiological assay. The most defensible interpretation is therefore a product-identity and mechanism overview, not evidence of assay efficacy, translational predictiveness, or clinical applicability.